Products
High Frequency Oil-Cooled Electrical Transformer
  • High Frequency Oil-Cooled Electrical TransformerHigh Frequency Oil-Cooled Electrical Transformer
  • High Frequency Oil-Cooled Electrical TransformerHigh Frequency Oil-Cooled Electrical Transformer
  • High Frequency Oil-Cooled Electrical TransformerHigh Frequency Oil-Cooled Electrical Transformer
  • High Frequency Oil-Cooled Electrical TransformerHigh Frequency Oil-Cooled Electrical Transformer
  • High Frequency Oil-Cooled Electrical TransformerHigh Frequency Oil-Cooled Electrical Transformer

High Frequency Oil-Cooled Electrical Transformer

Lugao Power Co., Ltd. offers the next generation of High Frequency Oil-Cooled Electrical Transformer, designed for superior power density and thermal management. Purchase High Frequency Oil-Cooled Electrical Transformer units that reduce energy loss by 30% compared to standard models. Ideal for heavy-duty industrial converters and renewable energy systems, our transformers feature a unique oil circulation path that eliminates hot spots. Ensure seamless procurement with Lugao’s global logistics and OEM customization.

The High Frequency Oil-Cooled Electrical Transformer by Lugao Power is specifically engineered to operate at frequencies ranging from 1kHz to 20kHz, a critical requirement for modern PWM inverters, induction heating equipment, and electric vehicle charging stations. Unlike standard 50/60Hz transformers that suffer from excessive core losses at higher frequencies, our units utilize advanced amorphous alloy or grain-oriented silicon steel cores combined with a specialized oil-immersed cooling system.

This design effectively manages the "skin effect" and proximity effect losses common in high-frequency operation. The oil not only acts as a superior dielectric insulator, providing high voltage withstand capability but also efficiently dissipates heat from the core and windings. This results in a compact footprint, higher power-to-weight ratio, and exceptional reliability in harsh environmental conditions.

High Frequency Oil Cooled Electrical TransformerHigh Frequency Oil Cooled Electrical Transformer

Product Parameters (Specification)

Our technical team can customize based on your specific requirements. Below are the standard ranges for the High Frequency Oil-Cooled Electrical Transformer:

Parameter

Standard Range

Custom Option

Rated Power

100 kVA to 10,000 kVA

Up to 20 MVA

Frequency Range

1 kHz – 5 kHz

6 kHz – 20 kHz

Primary Voltage

Up to 35 kV

66 kV / Custom

Secondary Voltage

400V – 3.3 kV

Custom impedance

Cooling Method

ONAN (Oil Natural)

OFAF (Forced Oil)

Vector Group

Dyn11, Yyn0

YNd11, Custom

Insulation Class

Class A (105°C)

Class H (180°C)

Efficiency

≥ 98.5%

Up to 99.1%

Standards

IEC 60076, IEEE C57.12

GB 1094


Product Features & Application (Q&A Format)

Q: Why choose oil-cooling over air-cooling for high-frequency applications?

A: High-frequency operation creates the "Skin Effect," where current flows on the surface of the conductor, generating intense localized heat. Air cooling is often insufficient for compact designs. Our oil-cooled solution surrounds the windings with a high-dielectric fluid that extracts heat 10x more efficiently than air. This prevents hot spots, extends insulation life, and allows the High Frequency Oil-Cooled Electrical Transformer to maintain 100% duty cycle operation even in 50°C ambient environments.


Q: How does Lugao Power solve the problem of "parasitic capacitance" at high frequencies?

A: This is a critical pain point. High frequency increases parasitic capacitance, leading to EMI noise and driver failure. At Lugao Power Co., Ltd. , we utilize a specialized interleaved winding technique combined with a DMD (Dacron Mylar Dacron) insulation barrier specific to oil immersion. This reduces parasitic capacitance by approximately 30% compared to standard layer-wound designs, ensuring clean switching waveforms.


Q: In which industries is this specific oil-cooled high-frequency model used?

A: The High Frequency Oil-Cooled Electrical Transformer excels in harsh conditions.

1. Renewable Energy: Wind converters and Solar PV inverters (grid isolation).

2. Marine & Deep Sea: ROVs and shipboard power (where salt spray and vibration are constant).

3. EV Charging: High-power off-board rapid chargers requiring compact footprints.

4. Railways: Auxiliary power supplies for high-speed trains.


Q: What is the maintenance schedule for the oil?

A: Minimal. Unlike standard power transformers that degrade oil due to arcing, our high-frequency units operate with lower steady-state flux. We recommend a dielectric strength test annually, but the oil typically lasts 10+ years due to the sealed, oxygen-free construction.

High Frequency Oil Cooled Electrical TransformerHigh Frequency Oil Cooled Electrical Transformer

Production Details & Quality Assurance

Core Manufacturing

We utilize ZDKH-75 high-speed slitting lines to ensure burrs on the silicon steel are < 0.02mm. For the High Frequency Oil-Cooled Electrical Transformer, this precision is vital to reduce eddy current losses at high switching speeds.


Winding & Assembly

Windings are produced on CNC-controlled machines to ensure precise tension. After winding, every unit undergoes a vacuum pressure impregnation (VPI) process before the oil is introduced. This removes all moisture from the cellulose insulation, preventing hydrogen outgassing during operation.


The "Lugao" Comparison Advantage

Feature

Competitors (Standard)

Lugao Power Solution

Core Material

Standard Silicon Steel

Amorphous / Nano-crystalline (Lower Loss)

Thermal Management

Passive / Radiator

Oil-Cooled Direct Contact

Acoustic Noise

High (70dB+)

Low (<55dB) – Silent operation

Warranty

1 Year

3 Years Standard / 5 Years Optional


Why Choose Lugao Power Co., Ltd.?

We are not just a factory; we are a solution provider. While many suppliers offer "high voltage" or "dry type" units, few master the physics of High Frequency Oil-Cooled Electrical Transformer design. We provide full type-test reports, including short-circuit and heat-run tests. Our logistics team ensures professional packaging (ISO 6583 certified wood + shock absorbers) for global sea/air freight.

High Frequency Oil Cooled Electrical TransformerHigh Frequency Oil Cooled Electrical Transformer

Client Procurement FAQs

Q1: Can you customize the impedance to match my IGBT switching circuit?

A: Yes. We adjust the leakage inductance precisely. Just provide your switching frequency (e.g., 16kHz) and topology (Full-bridge/LLC), and we will design the High Frequency Oil-Cooled Electrical Transformer to match.


Q2: What is the MOQ?

A: One piece. We support prototype development and small-batch pilot projects before mass production.


Q3: How do you prevent oil leakage during transit?

A: We ship units "dry" (oil separate) or "filled" depending on your preference. If filled, we pressurize the tank with dry air to 0.03MPa for 12 hours to verify zero pressure drop before shipping.


Q4: Do you provide samples for testing?

A: Absolutely. We encourage customers to test our efficiency metrics against their current suppliers. We are confident the High Frequency Oil-Cooled Electrical Transformer will outperform standard units in thermal imaging tests.


The design and testing of transformers shall comply with the following standards:

GB1094.1~2-1996, GB1094.3-2003, GB1094.5-2008 《Power Transformers》

GB/T6451-2015 《Specification and Technical Requirements for Oil-Immersed Power Transformers》

JB/T3837-2010 《Method of Compiling Type Designations for Transformer Products》

GB/T311.1-3.11-97 《Insulation Coordination and High Voltage Testing Techniques for High Voltage Transmission and Transformation Equipment》

GB10237-88 《Insulation Levels and Dielectric Tests for Power Transformers—External Insulation Air Clearances》

GB7595-87 《Quality Standard for Transformer Oil in Service》

GB7328-87 《Measurement of Sound Level for Transformers》

GB7534-87 《Measurement of Partial Discharge》

GB/T15164-94 《Loading Guide for Oil-Immersed Power Transformers》

DL/T586-95 《Technical Guide for Manufacturing Supervision of Power Equipment Users》

GB/T311.1-3.11-97 《Insulation Coordination and High Voltage Testing Techniques for High Voltage Transmission and Transformation Equipment》

GB2536-1990 《Transformer Oil》

JB/T56011-92 《Product Quality Classification for Oil-Immersed Power Transformers》

ZBK41005-89 《Sound Level of 6-220KV Transformers》

Send Inquiry
Contact Info

How to Get Your Custom Solution:

Share your specs: Voltage level (e.g., 11kV, 33kV), rated capacity (kVA/MVA), and installation environment (Indoor/Outdoor).

Our engineering review: We analyze your load profile and short-circuit requirements (2-4 hours).

Deliverables: You'll receive a preliminary GA drawing, technical datasheet, and commercial offer within 24 working hours.

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept